LG Split AC Error Code List Summary
LG Corporation, a multinational conglomerate corporation, was established in Busan, South Korea on January 5, 1947, by Koo In-Hwoi. The company’s headquarters is currently located in Seoul, South Korea. As of December 2021, the company has a workforce of 259,915 employees. Popular subsidiaries of LG Corporation include LG Electronics, LG Uplus, LG Chem, LG CNS, among others. If you are using an LG air conditioner, it is advisable to refer to the LG Split AC Error Code List PDF to better understand any potential errors.
LG Air Conditioner Error Codes – The Complete List:
Indoor Unit Faults
Error Code | Possible Cause | |||
1 | Indoor unit room temperature sensor error | |||
2 | Indoor unit inlet pipe sensor error | |||
4 | Float switch error (optional) | |||
5 | Communication error between indoor unit and outdoor units | |||
6 | Indoor unit outlet pipe sensor error | |||
9 | Indoor unit EPROM error | |||
10 | Indoor unit BLDC motor fan lock | |||
12 | Indoor unit middle pipe sensor error |
Outdoor Unit Faults
Error Code | Possible Cause | |||
21 | DC Peak (IPM Fault); Compressor DC voltage was too high | |||
22 | Current Transformed (CT2) error; Alternating current (AC) input too high | |||
23 | DC Link Low Volt | |||
25 | AC Low/High Volt | |||
26 | DC Comp Position Error (not providing rotation), Locking | |||
27 | PSC Fault; Current to inverter compressor between AC and DC converter circuit too high | |||
28 | Inverter compressor DC voltage is too high | |||
29 | Inverter compressor amperage is too high | |||
31 | Current-to-current transformer (CT) thermistor is too low | |||
32 | Inverter Compressor Discharge Pipe (D-Pipe) Overheat | |||
40 | CT Sensor Error; Thermistor is disconnected or shorted out | |||
41 | D-Pipe Sensor INV is disconnected or shorted out | |||
44 | Outdoor Air Sensor is disconnected or shorted out | |||
45 | Middle thermistor of outdoor unit condenser coil is disconnected or shorted out | |||
46 | Outdoor unit suction line thermistor is disconnected or shorted out | |||
48 | Outdoor unit coil outlet (liquid line) thermistor is disconnected or shorted out | |||
53 | Communication failure from outdoor unit to indoor unit | |||
60 | Outdoor unit printed circuit board (PCB) EPROM check sum error | |||
61 | Outdoor unit condenser coil temperature is too high | |||
62 | Outdoor unit inverter compressor PCB heat sink temperature is too high | |||
63 | Condenser coil pipe thermistor temperature is too low | |||
65 | Heat sink thermistor has disconnected or has shorted out | |||
67 | Outdoor brushless direct current (BLDC) fan motor lock error |
LED Error Codes
Error Code | Description | LED 01G/M (Red) | LED 01G/M (Red) | Possible Cause | ||||||
21 | DC Link Peak (IPM Fault) | 2 times 3 | 1 times 3 | Over Rated Current | ||||||
22 | CT 2 (Max CT) | 2 times 3 | Input Over Current | |||||||
23 | DC Link Low Volt. DC Link High Volt. | 3 times 3 | DC Link Volt is below 140Vdc DC Link Volt is above 420Vdc | |||||||
25 | Low Voltage/Over Voltage | 5 times 3 | Abnormal AC Volt Input | |||||||
26 | DC Compressor Position Error | 6 times 3 | Compressor Starting Fall Error | |||||||
27 | PSC/PFC Fault Error | 7 times 3 | Over Inverter PCB input current | |||||||
29 | COMP Over Current | 9 times 3 | Over Inverter Compressor Current | |||||||
32 | D-Pipe High | 3 times 3 | 2 times 3 | D-Pipe Temp. High | ||||||
35 | Low Pressure Error | 5 times 3 | Excessive decrease of Low Pressure | |||||||
39 | Communication Error | 9 times 3 | Communication Error Between PFC Micom and INV Micom | |||||||
40 | CT Sensor (Open/Short) | 4 times 3 | 0 | CT Circuit Malfunction | ||||||
41 | INV. D-Pipe Th Error | 1 times 3 | Open/Short | |||||||
43 | High Pressure Sensor Error | 3 times 3 | ||||||||
44 | Outdoor Air Th Error | 4 times 3 | ||||||||
45 | Cond. Mid-Pipe Th Error | 5 times 3 | ||||||||
46 | Suction Pipe Th Error | 6 times 3 | ||||||||
48 | Cond. Out-Pipe Th Error | 8 times 3 | ||||||||
51 | Capacity Over | 5 times 3 | 1 times 3 | Over combination | ||||||
53 | Signal Error (Indoor <-> Outdoor) | 3 times 3 | Communication Poorly | |||||||
54 | 3-Phase Wrong wiring | 4 times 3 | 3-Phase Wrong Wring of Outdoor Unit (Reverse Phase/Omission of Phase) | |||||||
60 | EEPROM Check Sum Error | 6 times 3 | 0 | Check Sum Mismatching | ||||||
61 | Cond. Pipe Th High | 1 times 3 | Cond. Temp. High | |||||||
62 | Heat sink Th High | 2 times 3 | Heatsink Temp. High | |||||||
65 | Heat sink Th Error | 5 times 3 | Open/Short | |||||||
67 | Outdoor BLDC Fan Lock | 7 times 3 | Outdoor Fan is not operation | |||||||
73 | PFC Fault Error(SAN) | 7 times 3 | 3 times 3 | Over Current of Outdoor Unit PFC |
Error Codes with Possible Causes
Error Code | Possible Cause | Indicator | Operating State | |||||||
2 | Outdoor TH. is short or open. | The operating LED will be blinking twice. | Keep operating state. | |||||||
4 | Temp. of Heat sink is over 95°C. Heat sink TH. is short or open. | The operating LED will be blinking 4 times. | Restart compressor when Heat sink Temp is 85°C below. | |||||||
5 | Communication error (serial communication). | The operating LED will be blinking 5 times. | The operation is off (enable to restart by remote controller). | |||||||
6 | DC peak error. | The operating LED will be blinking 6 times. | Compressor will be turned off immediately (not enable to restart by remote controller) | |||||||
7 | Running current is overloaded. | The operating LED will be blinking 7 times. | Compressor will be turned off immediately (not enable to restart by remote controller) | |||||||
9 | Outdoor fan lock error (BLDC fan model) | The operating LED will be blinking 9 times. | The operation is off (enable to restart by remote controller). | |||||||
10 | D-PIPE TH is short or open. | The operating LED will be blinking 10 times. | Compressor will be turned off immediately (restart compressor when D-PIPE TH. is recovered) | |||||||
Error Code | Possible Cause | Check/Repair | Shop Parts | |||||
1 | Temperature sensor failure | Unplug the air conditioner and check the wire harness connections on the electronic control board. Examine the electronic control board for damage. Check for a pinched or broken wire in the temperature sensor wire harness. Replace the temperature sensor if it’s defective. | Temperature sensor, Wire harness, Electronic control board | |||||
E2 | Failure in the indoor temperature sensor | Unplug the air conditioner and check the wire harness connections on the electronic control board. Examine the electronic control board for damage. Check for a pinched or broken wire in the indoor temperature sensor wire harness. Replace the indoor temperature sensor if it’s defective. | Indoor temperature sensor, Wire harness, Electronic control board | |||||
E3 | Abnormal operation protection error | Indoor temperature sensor, Wire harness, Electronic control board | ||||||
E3 | Clean or replace filters if dirty. Unplug the window air conditioner and check all components for visible damage. Check fan blades for damage or obstructions and replace any damaged fan blades. Check all wire harness connections. Replace any damaged wire harnesses. | Filter, Fan blade, Fan motor, Wire harness | ||||||
E4 (Portable A/C only) | The air conditioner is in the defrost mode | After the air conditioner exits defrost mode and resume normal operation, check the unit to see if it’s cooling properly. If so, then the E4 code is normal. If the portable air conditioner frequently goes into the defrost mode and isn’t cooling properly, check the air filters and clean or replace filters if dirty. | Filter | |||||
P2 or FL (Portable A/C only) | The water collection tank is full | Empty the water collection tank. If the P2 or FL code appears when the tank is empty, replace the float switch or sensor in the collection tank. | Collection tank float switch or sensor |
Error Codes with Description
Error Code | Function Name | Description | ||||
01 h | Read Coil Status | Run/Stop(status), Lock(status), Swing(status), Alarm, Filter Sign(status), Mode Lock(status), Wind Flow Lock(status) | ||||
03h | Read Holding Registers | Operation Mode(status), Fan Speed(status), Room Temperature, Error Code, Set Room Temperature(status), Set Lower Temperature(status), Set Upper Temperature(status), User Mode(status) | ||||
05h | Force Single Coil | Run/Stop(setting), Lock(setting), Swing(setting), Filter Sign Reset, Mode Lock(setting), Wind Flow Lock(setting) | ||||
06h | Preset Single Registers | Operation Mode(setting), Fan Speed(setting), Set Room Temperature(setting), Set Lower Temperature(setting), Set Upper Temperature(setting), User Mode(setting) |
Other Error Codes
Error Code | Possible Cause | Solution | ||||
Code appears in the display. F1,F2 or F3 | Air conditioner is in FAN mode and the number shown is the set fan speed. | This is normal. The air conditioner is working properly. | ||||
FL | The water collection tank is full. | Empty the water collection tank. | ||||
CH01 | Short or open circuit in the indoor air thermistor. | Unplug the air conditioner and contact your authorized LG service center. |